HVAC CONTROLS (See section 18.9) Thermostat (additional information) A thermostat is the example of a sensing device. Sensing devices of an HVAC control system sense air or water temperature, humidity, and steam pressure or air pressure, and convert the sensation into a transmittable signal. A thermostat signals the heating/cooling equipment when to start and stop and how much to modulate. The temperature difference between when the equipment is shut off and when it is called to restart is referred to as the "dead band." HVAC CONTROLS

When the room temperature falls below a specified set point for heating minus the thermostat dead band, the thermostat will call for heating. If the room temperature rises above a user-specified set point for cooling plus the dead band value, the thermostat will call for cooling. HVAC CONTROLS Thermostats must be located where they can sense the average temperature of the space to be conditioned. They should not be located where there is a possibility of exposure to conditions that are not

representative of the whole space. such as in direct sunlight, in a cold draft, on an outside wall, or near a heating or cooling surface. HVAC CONTROLS If the thermostat is desired to be concealed for certain reasons, a variation of the standard wall thermostat can be located in the return air duct. Thermostats are also available with remote-sensing wires which may be wrapped inconspicuously around an art object. HVAC CONTROLS

Self-contained microprocessor-based thermostats can be programmed for a wide range of daily setback cycles that can change for each day of the week. These devices are simple to operate and can control a number of different zones with separate sensors. Dampers (additional information) Circulating and controlling of air extensively involve dampers. HVAC CONTROLS Single blade: They are mostly manually operated and installed with a locking device, called a locking quadrant, by means of which they may be fixed in the desired position.

May also be automatic and may either be center or edge pivoted. Barometric: Usually made with fine-tune adjustment features and equipped with adjustable counterweights. Often used in the smoke pipe of a furnace or boiler to stabilize draft conditions and permit close adjustment of fuel burners. Multiblade: Used for control of large volumes of air moving at high or low velocities in large duct systems. They are of two types: parallel blade and opposed blade. In parallel blade type, all blades turn in same direction. In opposed blade type, alternate blade turns in opposite direction. NOISE AND VIBRATION (Additional information) Sound becomes noise when it is objectionable to the

occupants of a building. Without proper precautions, sounds generated by HVAC systems may become irritating noise. Sound is a by-product of energy supplied to the moving components of HVAC equipment. During the transformation of electrical or combustion energy into useful work, energy losses appear as heat, vibration, and sound. The items contributing the most sound are pumps, fans, compressors, and room air diffusers. NOISE AND VIBRATION The HVAC industry has established noise criteria (NC) values for evaluating the acceptability of sound levels. NC values for different types of buildings range from 30 to 40 decibels. A decibel is a unit of comparative sound measurement (a

whispered conversation at a distance of 6 ft. from the ear, for example, has a sound pressure level of 30 decibels). The noise level and vibration transmission can be partially controlled by mechanical isolation, shields, baffles, and acoustical liners. Massive concrete pads and vibration isolators are placed between the equipment and the building to avoid transmission of vibration and noise through the structure. Equipment rooms can be acoustically isolated if necessary. NOISE AND VIBRATION Rectangular ducts, particularly those with high aspect ratio, can transmit excessive noise if not properly supported. Round ducts are stronger and have better

aerodynamic characteristics, and therefore experience fewer noise problems. Registers and diffusers should be selected to minimize noise output. Equipment spaces should be separated as far as possible from spaces with demands for low background sound levels. Use of flexible fabric connections is recommended at points where the ductwork connects an equipment subject to vibration. MISCELLENEOUS (Additional information)

Aspect ratio It is the width to height ratio of an air supply device (e.g. a supply duct). A rectangular duct with an aspect ratio closer to one has lower frictional resistance. Aspiration ratio As supply air leaves a supply register, it has a certain volume of flow rate expressed in cfm; this is called primary air. As soon as this air leaves the outlet, it begins to attract air already existing in the room; this room air, called the secondary air, joins the primary air and is carried along with it. The moving air stream has now a much greater volume by the time it reaches the end of its throw.

This total volume, divided by the primary air volume is called the aspiration ratio. A high aspiration ratio is good, because it means that a greater quantity of air is kept in motion, with less chance of stagnation in parts of the room and with less chance of temperature stratification within the room.

Recently Viewed Presentations

  • Students of Concerns Team - ASCCC

    Students of Concerns Team - ASCCC

    Practices of a Students of Concerns Team Across Services. Grace Commiso & Dr. Nicky Damania. ... Rutgers Suicide - Tyler Clementi. 10 Behaviors to Look For. ... Dena Rhoades, Human Resource Manager.
  • Duty of Care - Defensive Engineering or the Crystal Ball

    Duty of Care - Defensive Engineering or the Crystal Ball

    The sale methods were often high pressure with false claims that to obtain a loan the cover was necessary . The dealers made extraordinarily high commissions and the cover was essentially useless ... The worst performer AMP , stated their...
  • LO: and common to errors errors able spelling

    LO: and common to errors errors able spelling

    Silent letters - structured output. Some of the words in this story have silent letters. Write out all of the words that have a silent 't,' 'c,' or 'h' in them in a table with three columns in your exercise...
  • Expanding MTSS/PBIS to Preschool through SPDG

    Expanding MTSS/PBIS to Preschool through SPDG

    Expanding MTSS/PBIS to Preschool through SPDG. Young Children with Challenging Behavior. ... Systems Model for Implementation and Scale-Up. Systems Thinking. ... National Center for Pyramid Model Innovations. www.challengingbehavior.org.
  • Introduction - National Transportation Safety Board

    Introduction - National Transportation Safety Board

    Collision Warning Systems Kristin Poland, Ph.D. Collision Warning Systems (CWS) Radar based Track other vehicles and stationary objects Prevent rear-end collisions Provide light and sound warnings Moving versus stationary objects Stationary Object Detection Perception/Reaction Times and CWS At 70 mph:...
  • Nincs diacím - Az atomoktól a csillagokig

    Nincs diacím - Az atomoktól a csillagokig

    A társadalmi össznyeremény minimális Végtelen hatótáv, véletlen partnerek Változó szomszédszám hatása Santos et al., PRL (2005) a valósághű társadalmi kapcsolatrendszerekben z helyről helyre változhat skálamentes hálózat [f(z)~z -3] (e.g., BA and DMS models) Ha stratégia-átvétel valószínűsége a teljes nyeremény ...
  • Linguistics II LI2023

    Linguistics II LI2023

    SEMANTICS LI 2013 NATHALIE F. MARTIN * * * * * * * * * * The symbol or a word signifies "things" by virtue of the "concept" associated with the form of the word in the minds of the...
  • Showing you my art smarts. - kms.nkschools.org

    Showing you my art smarts. - kms.nkschools.org

    BY: JESSICA ART IN MY WORLD About me…. My name is Jessica I am 11 years old I enjoy swimming I love MEAT but prefer turkey/chicken legs My favorite band is Panic!