Product Data Sheet00813-0100-4485, Rev AAApril 2010Rosemount DP FlowRosemount DP Flowmeters andPrimary Elements Multivariable capabilities allow for real timefully compensated mass and energy flow Fully-Integrated Wireless Flowmeters allowfor easy installation Minimize permanent pressure loss and saveenergy with Annubar Technology Reduce straight pipe requirements to twodiameters upstream and downstream fromany flow disturbance with Conditioning OrificePlate Technology Improve accuracy and repeatability in smallline sizes with Integral Orifice PlateTechnologyContentsDP Flow Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2Ordering Information, Specifications, and CertificationsRosemount 3051SF Flowmeter Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4Rosemount 3051CF Flowmeter Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41Rosemount 2051CF Flowmeter Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 64Rosemount 485 Annubar Primary Element. . . . . . . . . . . . . . . . . . . . . . . . . . . . page 86Rosemount 585 Annubar Primary Element. . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 94Rosemount 405 Compact Primary Element. . . . . . . . . . . . . . . . . . . . . . . . . . . .page 101Rosemount 1595 Conditioning Orifice Plate. . . . . . . . . . . . . . . . . . . . . . . . . . .page 105Rosemount 1195 Integral Orifice Primary Element . . . . . . . . . . . . . . . . . . . . . .page 108Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 113Installation and Flowmeter Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 151www.rosemount.com

Product Data SheetRosemount DP Flow00813-0100-4485, Rev AAApril 2010DP Flowmeter Selection GuideRosemount integrated DP Flowmeters arrive fully assembled, configured and leak tested for out-of-the-boxinstallation.Rosemount 3051SF Flowmeters enable best-in-class flow measurementutilizing advanced functionality Up to 0.80% mass flow rate accuracy Multivariable capabilities allow for real time fully compensated mass and energyflow Advanced diagnostics predict and prevent abnormal process conditions Installation ready wireless flow solution Ultra for Flow measures %-of-reading performance over 14:1 flow turndown 10-year stability, 12-year warrantyRosemount 3051CF Flowmeters combine the proven 3051C pressuretransmitter and the latest primary element technology Up to 1.65% volumetric flow accuracy at 8:1 turndown Available with HART , FOUNDATION fieldbus, and Profibus Protocols 5-year stabilityRosemount 2051CF Flowmeters combine the 2051C pressure transmitter andthe latest primary element technology Up to 2.00% volumetric flow accuracy at 5:1 turndown Available with HART, and FOUNDATION fieldbus Protocols 2-year stability2

Product Data Sheet00813-0100-4485, Rev AAApril 2010Rosemount DP FlowRosemount Annubar Primary Element Technology Energy savings gained through minimal permanent pressure loss Innovative T-shape design that increases accuracy to 0.75% of flow rate Variety of sensor materials for optimal compatibility with the process fluid Handles applications where conditions exceed the structural limitations ofother primary elements Symmetrical sensor design allows bi-directional flow measurementRosemount Conditioning Orifice Plate Technology Reduce straight pipe requirements to two diameters upstream anddownstream from any flow disturbance Discharge coefficient uncertainty of 0.5% Integral thermowell enables fully compensated mass flow with a single pipepenetration Reduce installation costs compared to traditional orifice plates with thecompact design Conditioning orifice plate is based on AGA, ASME and ISO industrystandards Available in various plate styles providing installation flexibilityRosemount Integral Orifice Plate Technology Improves accuracy and repeatability in 1/2-in., 1-in., and 1 1/2-in. line sizes Self-centering plate design eliminates installation errors that are magnified insmall line sizes Precision honed pipe sections allow accuracy of up to 0.75% of flow rate Installation flexibility with numerous process connections Integral thermowell enables fully compensated mass flow3

Product Data Sheet00813-0100-4485, Rev AAApril 2010Rosemount DP FlowRosemount 3051SF Flowmeter SeriesRosemount 3051SF Flowmeters integrate industry leading transmitters withindustry leading primary elements. Capabilities include:3051SFC3051SFA3051SFP Flowmeters are factory configured to meet your application needs(Configuration Data Sheet required) MultiVariable capabilities allow scalable flow compensation(Measurement Types 1 -7) HART 4-20, WirelessHART , and FOUNDATION fieldbus protocols Ultra for Flow for improved flow performance across wider flow ranges Integral temperature measurement (T option) Direct or remote mount configurations availableAdditional InformationSpecifications: page 25Product Certifications: Measurement Types 1-7: page 34Measurement Type D: page 36Wireless: page 39Dimensional Drawings: page 113Installation and Flowmeter Orientation: page 151Rosemount 3051SFA Annubar Flowmeter Annubar flowmeters reduce permanent pressure loss by creating less blockage in the pipe Ideal for large line size installations when cost, size and weight of the flowmeter are concernsTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.MeasurementType Available— UnavailableModelProduct DescriptionD1-73051SFAAnnubar Flowmeter — Standard —————— — Standard Measurement TypeStandard1234567DMultiVariable (Fully Compensated Mass & Energy Flow) – Differential & Static Pressures w/TemperatureMultiVariable (Compensated Flow) – Differential & Static PressuresMultiVariable (Compensated Flow) – Differential Pressure & TemperatureMultiVariable (Compensated Flow) – Differential PressureMultiVariable (Direct Measurement) – Differential & Static Pressures with TemperatureMultiVariable (Direct Measurement) – Differential & Static PressuresMultiVariable (Direct Measurement) – Differential Pressure & TemperatureDifferential PressureFluid TypeStandardLGS4LiquidGasSteam

Product Data Sheet00813-0100-4485, Rev AAApril 2010Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Line -72-in. (50 mm)21/2-in. (63.5 mm)3-in. (80 mm)31/2-in. (89 mm)4-in. (100 mm)5-in. (125 mm)6-in. (150 mm)7-in. (175 mm)8-in. (200 mm)10-in. (250 mm)12-in. (300 mm) 14-in. (350 mm)16-in. (400 mm)18-in. (450 mm)20-in. (500 mm)24-in. (600 mm)30-in. (750 mm)36-in. (900 mm)42-in. (1066 mm)48-in. (1210 mm)60-in. (1520 mm)72-in. (1820 mm)78-in (1950 mm)84-in. (2100 mm)90-in. (2250 mm)96-in (2400 mm) Range C from the Pipe I.D. tableRange D from the Pipe I.D. table Range A from the Pipe I.D. tableRange B from the Pipe I.D. tableRange E from the Pipe I.D. tableNon-standard Pipe I.D. Range or Line Sizes greater than 12-in. (300 mm) Carbon steel (A105)316 Stainless SteelNo Mounting (Customer Supplied) Chrome-Moly Grade F-11Chrome-Moly Grade F-22Chrome-Moly Grade F-91 Standard Pipe I.D. RangeStandardCDExpandedABEZStandard Pipe Material / Mounting Assembly MaterialStandardCS0(1)ExpandedGNJStandard Piping OrientationStandardHDUHorizontal PipingVertical Piping with Downwards FlowVertical Piping with Upwards FlowStandard 5

Product Data Sheet00813-0100-4485, Rev AAApril 2010Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Annubar TypeStandardPFExpandedLGMD1-7Pak-LokFlanged with opposite side support Flange-LokGear-Drive Flo-TapManual Flo-Tap 316 Stainless Steel Alloy C-276 Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm)Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm)Sensor size 3 — Line sizes greater than 12-in. (300 mm) Standard Compression or Threaded Connection150# RF ANSI300# RF ANSI600# RF ANSIDN PN16 FlangeDN PN40 FlangeDN PN100 Flange Standard 900# RF ANSI1500# RF ANSI2500 # RF ANSI150# RTJ Flange300# RTJ Flange600# RTJ Flange900# RTJ Flange1500# RTJ Flange2500# RTJ Flange Standard Standard Sensor MaterialStandardSExpandedHStandard Sensor SizeStandard123Mounting 1R3R6R9(2)RF(2)RT(2)Opposite Side Support or Packing GlandStandard0CDExpandedJKLNR6No opposite side support or packing gland (Required for Pak-Lok and Flange-Lok models)Opposite Side Support – Required for Flanged ModelsNPT Threaded Opposite Support Assembly – Extended TipWelded Opposite Support Assembly – Extended TipPacking Gland – Required for Flo-Tap ModelsPacking Gland MaterialStainless Steel Packing Gland / Cage NippleStainless Steel Packing Gland / Cage NippleStainless Steel Packing Gland / Cage NippleStainless Steel Packing Gland / Cage NippleAlloy C-276 Packing Gland / Cage NippleRod MaterialCarbon SteelStainless SteelCarbon SteelStainless SteelStainless SteelPacking MaterialPTFEPTFEGraphiteGraphiteGraphite

Product Data Sheet00813-0100-4485, Rev AAApril 2010Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Isolation Valve for Flo-Tap ModelsStandard0(1)Expanded1256D1-7Not Applicable or Customer Supplied Gate Valve, Carbon SteelGate Valve, Stainless SteelBall Valve, Carbon SteelBall Valve, Stainless Steel Integral RTD – not available with Flanged model greater than class 600#No Temperature Sensor Remote Thermowell and RTD Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than class600Direct -mount, 5-valve Manifold – not available with Flanged model greater than class 600Remote-mount NPT Connections (1/2-in. FNPT) Standard Direct-mount, High Temperature 5-valve Manifold – not available with Flanged model greaterthan class 600Remote-mount SW Connections (1/2-in.) Standard ———— Standard ——Standard — ———Standard Standard Temperature MeasurementStandardT(3)0(4)ExpandedR(3)Standard Transmitter Connection PlatformStandard357Expanded68Differential Pressure RangeStandard1230 to 25 in H2O (0 to 62,3 mbar)0 to 250 in H2O (0 to 623 mbar)0 to 1000 in H2O (0 to 2,5 bar)Static Pressure RangeStandardA(5)DE(6)JK(6)NoneAbsolute 0.5 to 800 psia (0,033 to 55,2 bar)Absolute 0.5 to 3626 psia (0,033 to 250 bar)Gage -14.2 to 800 psig (-0,979 to 55,2 bar)Gage -14.2 to 3626 psig (-0,979 to 250 bar)Transmitter OutputStandardAFX(7)4–20 mA with digital signal based on HART protocolFOUNDATION fieldbus protocol (requires PlantWeb housing)Wireless (Requires wireless options and Wireless Plantweb housing)Transmitter Housing StyleStandard001A1B1J1K2A2B2ENone (Customer-supplied electrical connection)PlantWeb HousingPlantWeb HousingPlantWeb HousingPlantWeb HousingJunction Box HousingJunction Box HousingJunction Box housing with output for remote display AluminumAluminumConduit EntrySize1/2-14 NPTM20 x 1.51/2-14 NPTM20 x 1.51/2-14 NPTM20 x 1.51/2-14 NPT7

Product Data Sheet00813-0100-4485, Rev AAApril 2010Rosemount DP FlowTable 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.2F2J2M5A5J7J(7)(8)Expanded1C1L2C2GJunction Box housing with output for remote display andinterfaceJunction Box HousingJunction Box housing with output for remote display andinterfaceWireless PlantWeb housingWireless PlantWeb housingQuick Connect (A size Mini, 4-pin male termination)AluminumM20 x 1.5 — SSTSST1 —— AluminumSST1 ——— PlantWeb HousingPlantWeb HousingJunction Box HousingJunction Box housing with output for remote display 2G1/2 ——D1-7/2-14 NPT/2-14 NPT1/2-141/2-14NPTNPTTransmitter Performance ClassStandard3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 63Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability. limited 12-yearwarranty5Classic MV: 0.85% flow rate accuracy, 8:1 flow turndown, 5-yr. stability3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D1Ultra: up to 0.9% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited 12-yearwarranty2Classic: up to 1.1% flow rate accuracy, 8:1 flow turndown, 5-year stability3(9)Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability. limited 12-yearwarrantyStandard — — — —Standard — — — Wireless Options (Requires option code X and wireless PlantWeb housing)Update Rate, Operating Frequency and ProtocolStandardWAUser Configurable Update RateOperating Frequency and ProtocolStandard32.4 GHz DSSS, WirelessHARTOmnidirectional Wireless AntennaStandardWK(10)Long Range, Integral AntennaSmart