Test Report issued under the responsibility of:TEST REPORTIEC 60065Audio, Video and Similar Electronic Apparatus: Safety RequirementsReport Reference No. .100094189CLE-001Date of issue .2011-10-28; Modification1: 2012-01-16Total number of pages .Modification 1: 5Prepared By:Carlos Cajica-SierraReviewed By:Modification 1: Rick JohnsonTesting Laboratory .Intertek Testing Services NA, Inc.Address .2307 East Aurora Road, Unit B7Twinsburg, OH 44087, USAApplicant’s name .Dr. Z AmplificationAddress .17011 Broadway Ave.Maple Hts. OH 44137Test specification:Standard.IEC 60065 : 2001 (7th Edition ) Amendment 1Test procedure. ETL Testing LabNon-standard testmethod .:NATest Report Form No. .IEC60065FTest Report Form(s) Originator.ASTA BEABMaster TRF .Dated 2006-09Copyright 2006 IEC System for Conformity Testing and Certification of Electrical Equipment(IECEE), Geneva, Switzerland. All rights reserved.This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged ascopyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting fromthe reader's interpretation of the reproduced material due to its placement and context.If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CBScheme procedure shall be removed.This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory andappended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.Test item description. Guitar AmplifiersTrade Mark.Manufacturer . Dr Z Amplification

Page 2 of 5Report No. 100094189CLE-001Modification 1: January 16, 2012Model/Type reference . ZA-18, ZA-8, ZA-7, ZA-15, ZA-30, ZA-31, ZA-20, ZA-5, ZA-22, ZA-10,ZA-27, ZA-26, ZA-28Ratings . 230VAC, 50Hz, 205W max.Refer to table below for specific model differences and ratings.

Page 3 of 5Report No. 100094189CLE-001Modification 1: January 16, 2012Summary of testing:Tests performed (name of test and test clause):TEST PERFORMEDDurability of MarkingsTestInput TestTemperature TestDetermination ofHazardous Live PartsTestDielectric WithstandTestInsulation ResistanceTestFault conditions TestsBump TestVibration TestImpact TestsCreepage andClearance TestEarth Resistance TestStability TestsTesting location:PARAGRAPHIntertek Testing Services NA,Inc.55.1-7.12307 East Aurora Road, UnitB77.1Twinsburg, OH 44087, USA9.1.1.110.3Vibration Test Only:4700 Broadmoor SE, Suite 200Kentwood, MI 49512, y of compliance with National Differences: None-AddressedCopy of marking plate representative of all models covered in this report (includes Cautionary andFrench Markings)

Page 4 of 5Report No. 100094189CLE-001Modification 1: January 16, 2012Test item particulars . :Classification of installation and use . : Class I, Overvoltage Category IISupply Connection . : 230 VAC Mains operation. Detachable Cordconnected. :Possible test case verdicts:- test case does not apply to the test object.: NA- test object does meet the requirement .: P (Pass)- test object does not meet the requirement .: F (Fail)Testing .:Date of receipt of test item .: 2011-05-24Date (s) of performance of tests .: 2011-05-25 to 2011-10-13General remarks:The test results presented in this report relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory."(see Enclosure #)" refers to additional information appended to the report."(see appended table)" refers to a table appended to the report.Throughout this report a point is used as the decimal separator.General product information:The products evaluated in this report are portable guitar amplifiers. The amplifiers are detachable, cordconnected units for household and professional use. Units are for indoor use only.These units have not been evaluated for use in tropical climates.Modification 1:The original test report 100094189CLE-001, dated 2011-10-28 was modified on 2012-01-16 under Intertekproject G100094189 to correct the following: On Table 14: list of critical components and materials: Second item, Power/Standby Switches, hadan incorrect part number associated with it. The part number listed is “1112 R.” the part number isbeing replaced by “110-63”. The component has not changed. This is a non-technical, typocorrection. No additional testing or construction was deemed necessary.

Page 5 of 514Report No. 100094189CLE-001Modification 1: January 16, 2012TABLE: list of critical components and materialsObject/Part No.Power/ /ModelTechnical Data )1112 RModification 1:110-63Rated 3A, 250V,6A, 125V.Mechanicallysecured ontoenclosure by nutsand washersStandardMark(s) of1Conformity )IEC 60065 Tested as part ofthe complete endproduct

Test Report issued under the responsibility of:TEST REPORTIEC 60065Audio, Video and Similar Electronic Apparatus: Safety RequirementsReport Reference No. .100094189CLE-001Date of issue .2011-10-28Total number of pages .51Prepared By:Carlos Cajica-SierraReviewed By:Zekarias BekeleTesting Laboratory .Intertek Testing Services NA, Inc.Address .2307 East Aurora Road, Unit B7Twinsburg, OH 44087, USAApplicant’s name .Dr. Z AmplificationAddress .17011 Broadway Ave.Maple Hts. OH 44137Test specification:Standard.IEC 60065 : 2001 (7th Edition ) Amendment 1Test procedure. ETL Testing LabNon-standard testmethod .:NATest Report Form No. .IEC60065FTest Report Form(s) Originator.ASTA BEABMaster TRF .Dated 2006-09Copyright 2006 IEC System for Conformity Testing and Certification of Electrical Equipment(IECEE), Geneva, Switzerland. All rights reserved.This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged ascopyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting fromthe reader's interpretation of the reproduced material due to its placement and context.If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CBScheme procedure shall be removed.This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory andappended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.Test item description. Guitar AmplifiersTrade Mark.Manufacturer . Dr Z Amplification

Model/Type reference . ZA-18, ZA-8, ZA-7, ZA-15, ZA-30, ZA-31, ZA-20, ZA-5, ZA-22, ZA-10,ZA-27, ZA-26, ZA-28Ratings . 230VAC, 50Hz, 205W max.Refer to table below for specific model differences and ratings.

Page 3 of 51Report No. 100094189CLE-001Summary of testing:Tests performed (name of test and test clause):TEST PERFORMEDDurability of MarkingsTestInput TestTemperature TestDetermination ofHazardous Live PartsTestDielectric WithstandTestInsulation ResistanceTestFault conditions TestsBump TestVibration TestImpact TestsCreepage andClearance TestEarth Resistance TestStability TestsTesting location:PARAGRAPHIntertek Testing Services NA,Inc.55.1-7.12307 East Aurora Road, UnitB77.1Twinsburg, OH 44087, USA9.1.1.110.3Vibration Test Only:4700 Broadmoor SE, Suite 200Kentwood, MI 49512, y of compliance with National Differences: None-AddressedCopy of marking plate representative of all models covered in this report (includes Cautionary andFrench Markings)TRF No. IEC60065F

Page 4 of 51Report No. 100094189CLE-001Test item particulars . :Classification of installation and use . : Class I, Overvoltage Category IISupply Connection. : 230 VAC Mains operation. Detachable Cordconnected. :Possible test case verdicts:- test case does not apply to the test object.: NA- test object does meet the requirement .: P (Pass)- test object does not meet the requirement .: F (Fail)Testing .:Date of receipt of test item .: 2011-05-24Date (s) of performance of tests .: 2011-05-25 to 2011-10-13General remarks:The test results presented in this report relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory."(see Enclosure #)" refers to additional information appended to the report."(see appended table)" refers to a table appended to the report.Throughout this report a point is used as the decimal separator.General product information:The products evaluated in this report are portable guitar amplifiers. The amplifiers aredetachable, cord connected units for household and professional use. Units are for indooruse only.These units have not been evaluated for use in tropical climates.TRF No. IEC60065F

Page 5 of 51Report No. 100094189CLE-001IEC 60065ClauseRequirement – Test3GENERAL REQUIREMENTSResult - RemarkSafety class of the apparatus . : Unit is a Class I device. All accessibleconductive parts are connected to theprotective earthing conductor.4GENERAL CONDITIONS OF TESTS4.1.4Ventilation instructions require the use of the testbox5VerdictPPTemperature Test was conducted withoutimpeding ventilationMARKINGComprehensible and easily discernibleThe Model numbers of the unit are easilyreadablePPermanent durability against water and petroleumspiritDurability of marking test has beenperformed and found compliant.Markings are silkscreen, painted on theenclosure. Test was performed byrubbing the areas for 15 seconds on thefollowing areas:P Ratings area: Rubbed withwater and Petroleum Spirits:Marking remained legible. Nocurling Cautionary Marking (Shockhazard marking): Rubbed withwater and petroleum Spirits:Marking remained legible. NocurlingMaterials used:1) Methanol Spirits, expiration duedate 09/01/20122) Stopwatch, SW012, Cal. duedate 01/19/20123) Humidity and Temperaturerecorder: HT024, cal. Due date:03/21/2012Test date: 10/16/2011Test conditions: 24.5 C, 45% RH5.1a), b)Identification, maker, model . : Z-AMP, Model numbers of the units havebeen providedc)Class II symbol if applicabled), e)Rated supply voltage and symbol . : 230 V Pf)Frequency if safety dependantPg), h), i)Rated current or power consumption . : Input Test was conducted to verifyratings. Refer to Table 7.1 for test data.TRF No. IEC60065FUnit is Class IP50HzNAP

Page 6 of 51Report No. 100094189CLE-001IEC 60065ClauseRequirement – TestResult - Remark5.2Earth terminalEarth connection is achieved by using anNRTL approved appliance inlet whichcontains an Earth pin suitable for itsintended use.b)Hazardous live terminalsNo hazardous live terminal that cancause operator harm under normaloperating condition other than Mainsc)Supply output terminals (other than mains)Output terminals are clearly marked withthe type reference of the apparatuses tobe used.P5.3Use of triangle with exclamation markThe warning mark is used in theoperator’s manual page 2 as well as theunit.Operation of the unit is stated in theInstructions for useOperator’s Manual on page 3&4. All ofthe required instructions applicable to theunit and per sub-clauses 1 through 14have been provided, reviewed anddeemed complaint with the requirementsof the standard. Refer to OperationsManual Rev 11-Dec-07 present on file.Mains powered equipment not exposed to dripping Marking is provided in manual.or splashing. Warning concerning objects filled withliquid, etc.Pb)Hazardous live terminals, instructions for wiringLive hazardous parts exists inside theenclosure and a warning symbol andinstruction is stated in the instructionmanualPc)Instructions for replacing lithium batteryIt’s not a battery operated unitPInstructions for modem if fittedNo modem fitted on this unitPd)Class I earth connection warningMain plug socket has plug with earthground (three prongs)Pe)Instructions for multimedia system connectionNo such multimedia connectionf)Special stability warning for fixed installationStability test was performed per clause19.1 and found compliant to therequirements of the standa